Default Ness 5000

Got a Ness5000 that I need to change the dialler settings on.

The dialler has had a code put on it and the code is not known. Im not talking about the panel installer code either.

Can anyone tell me if I default the panel via the standard method will the Dialler code default as well?
ATech is offline   Reply With Quote
Old 28-09-08, 01:05 PM   #2 (permalink)
Member
 

iTrader: (0)
Join Date: Jan 2008
Posts: 78
Spent time on board: 1 Day and 2:15:02
Tastech is on a distinguished road
Default

If you access the panel programming using the lid off method all current programming will remain
Tastech is offline   Reply With Quote
Old 28-09-08, 01:12 PM   #3 (permalink)
Senior Member
 

iTrader: (0)
Join Date: Jan 2008
Posts: 276
Spent time on board: 1 Day and 20:30:36
keef82 is on a distinguished road
Default

I would change it to a new panel mate
that thing is a dinosaur lol..
keef82 is offline   Reply With Quote
Sponsored Links
Old 28-09-08, 03:05 PM   #4 (permalink)
Junior Member
 

iTrader: (0)
Join Date: Feb 2008
Posts: 17
Spent time on board: 16:23:56
ATech is on a distinguished road
Default

Client does not want a new panel as this one has been reliable. lol

Tastech, there is a seperate code that can be enabled to limit access to just the dialler programming.

I have had no probs getting into panel programming via the method you describe but once in there it wont let me alter dialler options.
ATech is offline   Reply With Quote
Old 28-09-08, 03:28 PM   #5 (permalink)
Premium Member
 

iTrader: (1)
Join Date: Jan 2008
Location: Australia
Posts: 213
Spent time on board: 1 Week, 6 Days and 6:12:41
bss904 is on a distinguished road
Default

Quote:
Originally Posted by ATech View Post
Client does not want a new panel as this one has been reliable. lol

Tastech, there is a seperate code that can be enabled to limit access to just the dialler programming.

I have had no probs getting into panel programming via the method you describe but once in there it wont let me alter dialler options.



Just whisper the word "lightning" to the panel and it will shit itself then it will have to be replaced.
bss904 is offline   Reply With Quote
Old 28-09-08, 03:36 PM   #6 (permalink)
Senior Member
 

iTrader: (0)
Join Date: Jan 2008
Posts: 276
Spent time on board: 1 Day and 20:30:36
keef82 is on a distinguished road
Default

Lol
keef82 is offline   Reply With Quote
Sponsored Links
Old 28-09-08, 03:36 PM   #7 (permalink)
Senior Member
 

iTrader: (0)
Join Date: Jan 2008
Posts: 276
Spent time on board: 1 Day and 20:30:36
keef82 is on a distinguished road
Default

Quote:
Originally Posted by ATech View Post
Client does not want a new panel as this one has been reliable. lol

Tastech, there is a seperate code that can be enabled to limit access to just the dialler programming.

I have had no probs getting into panel programming via the method you describe but once in there it wont let me alter dialler options.

Leave the old beast alone :P as soon as u touch any programming
"RIP"
LOL
keef82 is offline   Reply With Quote
Old 28-09-08, 04:31 PM   #8 (permalink)
Junior Member
 

iTrader: (0)
Join Date: Feb 2008
Posts: 17
Spent time on board: 16:23:56
ATech is on a distinguished road
Default

I dont particulary like them but they cant be too bad as there are still plenty of them working today 20 odd years after being turned on.

So know one knows the answer to my question eh.
ATech is offline   Reply With Quote
Old 28-09-08, 05:17 PM   #9 (permalink)
Senior Member
 

iTrader: (0)
Join Date: Jan 2008
Posts: 276
Spent time on board: 1 Day and 20:30:36
keef82 is on a distinguished road
Default

I don;t know if there is a back door way into the dialler if a seperate installer code was set. Maybe ness will reset it still? but i doubt it.
keef82 is offline   Reply With Quote
Sponsored Links
Old 28-09-08, 05:18 PM   #10 (permalink)
Senior Member
 

iTrader: (0)
Join Date: Jan 2008
Posts: 276
Spent time on board: 1 Day and 20:30:36
keef82 is on a distinguished road
Default

I have an old manual some where, let me look for it mate.
keef82 is offline   Reply With Quote
Old 28-09-08, 05:35 PM   #11 (permalink)
Premium Member
 

iTrader: (1)
Join Date: Jan 2008
Location: Australia
Posts: 213
Spent time on board: 1 Week, 6 Days and 6:12:41
bss904 is on a distinguished road
Default

What do you specifically want to change.
Are you a tech or an end user.
The answer to your questions are on page 6 & 7 of the dialler manual.
If you don't know the lock code then you can default just the dialler and reprogram it again. Not a great deal of addresses to reprogram.
Have you rung ness for tech support.
bss904 is offline   Reply With Quote
Old 28-09-08, 06:47 PM   #12 (permalink)
Junior Member
 

iTrader: (0)
Join Date: Feb 2008
Posts: 17
Spent time on board: 16:23:56
ATech is on a distinguished road
Default

I need to change Primary/secondary reciever numbers as well as account number. Oh and the timer test interval.

Left 2 messages on Ness tech support answering service mid last week but they must be busy as I havn't got a return call as yet.

Bss904 you must have a different dialler manual to me as the answer to my questions is not in there on mine. But thanks anyway.

Thanks Keef. I have the install & dialler manuals too but have not found the answer to my question.

I dont want to default it and find that all settings wiped ok but still cant get in to reprogram the dialler like a C&K236i.
ATech is offline   Reply With Quote
Sponsored Links
Old 28-09-08, 09:33 PM   #13 (permalink)
Junior Member
 
FordTech's Avatar
 

iTrader: (0)
Join Date: Jan 2008
Posts: 15
Spent time on board: 0:18:05
FordTech is on a distinguished road
Default

You will have to default the dialler, instructions are in the dialler programming manual. There is probably no one at Ness who would no how to program a 5000 now lol.
FordTech is offline   Reply With Quote
Old 28-09-08, 10:04 PM   #14 (permalink)
Junior Member
 

iTrader: (0)
Join Date: Feb 2008
Posts: 17
Spent time on board: 16:23:56
ATech is on a distinguished road
Default

Thanks for that FordTech
ATech is offline   Reply With Quote
Old 29-09-08, 06:36 AM   #15 (permalink)
Registered User
 
manicretep's Avatar
 

iTrader: (0)
Join Date: Jul 2008
Location: Da boondocks
Posts: 94
manicretep is on a distinguished road
Default

Quote:
Originally Posted by FordTech View Post
You will have to default the dialler, instructions are in the dialler programming manual. There is probably no one at Ness who would no how to program a 5000 now lol.



Peter Burns @ Ness BRIS, been there for 20+ Yrs,
manicretep is offline   Reply With Quote
Sponsored Links
Old 30-09-08, 08:39 AM   #16 (permalink)
Junior Member
 
MCman's Avatar
 

iTrader: (0)
Join Date: Jan 2008
Posts: 4
Spent time on board: 3:36:03
MCman is on a distinguished road
Default

Quote:
Originally Posted by manicretep View Post
Peter Burns @ Ness BRIS, been there for 20+ Yrs,
or Warren, Darrin, Jack in Syd, Greg and Peter in Melb or Graham in Perth all 20+yrs.

Whisper lightning to any panel and you will have trouble.

You will have no trouble if you contact a branch and ask for one of these guys.

Regards MCman
MCman is offline   Reply With Quote
Old 30-09-08, 02:12 PM   #17 (permalink)
Junior Member
 

iTrader: (0)
Join Date: May 2008
Posts: 19
Spent time on board: 3:53:49
Paulypudding is on a distinguished road
Default Ness

Hi there

If you have the correct manuals it will tell you how to default the dialler. You wont be able to get into the dialler programming if a code has been entered so when you default it you will lose all the other info as well. Alarm and restore codes, test times, tamper alarms, and a few others. Peter Burns at ness is very helpful. It's very easy to reprogram them but may seem difficult if you havent done it before. There are still hundreds of Ness 5000 panels out there and have survived very well. There are no replacement parts anymore. When the keypad membranes go you wont be able to replace them either, but saying that they are still a pretty good basic panel. I would go down the upgrade option myself but if the client doesnt want that then I suppose you will get extra work eventually when it does fail.

If you dont get any further with suitable help then contact me via my pm and I'll give you more details

Paul
Paulypudding is offline   Reply With Quote
Old 03-10-08, 04:11 AM   #18 (permalink)
Member
 
redozqld's Avatar
 

iTrader: (0)
Join Date: Aug 2008
Location: Here in Brisbane
Posts: 39
Spent time on board: 11:28:55
redozqld is on a distinguished road
Default

Quote:
Originally Posted by bss904 View Post
Just whisper the word "lightning" to the panel and it will shit itself then it will have to be replaced.


Only if they havent had the lightning arrestor modification done to them, and of course, making sure that the arrestor has been suitably earthed always helps (Had a turkey many years ago put the lightning kit because the poor old securitel board kept on being fried, didnt bother to earth it, then it blew up again... hrmmm the funny thing, is that it had a small lead that came off the board from the gas arrestor, he/she/it cut the cable off flush with the pcb...

Ness 5000's are not bad, they where just built that way ... a la Jessica Rabbit...

ReD
redozqld is offline   Reply With Quote
Sponsored Links
Old 03-10-08, 04:13 AM   #19 (permalink)
Member
 
redozqld's Avatar
 

iTrader: (0)
Join Date: Aug 2008
Location: Here in Brisbane
Posts: 39
Spent time on board: 11:28:55
redozqld is on a distinguished road
Default

Quote:
Originally Posted by ATech View Post
Got a Ness5000 that I need to change the dialler settings on.

The dialler has had a code put on it and the code is not known. Im not talking about the panel installer code either.

Can anyone tell me if I default the panel via the standard method will the Dialler code default as well?

Heya ATech, if your having troubles with the beast I have all the old 5000's manuals (Even got some of the original blue booklets) plus all the programming guides for the early ness stuff that you may come accross... If you would like them PM Me and I'll shoot you over the manuals in pdf.

ReD
redozqld is offline   Reply With Quote
Old 03-10-08, 08:39 AM   #20 (permalink)
Junior Member
 

iTrader: (0)
Join Date: Feb 2008
Posts: 17
Spent time on board: 16:23:56
ATech is on a distinguished road
Default

Thanks for the info guys.
I got the manuals but thanks for the offer Redozqld.
I saw the page on defaulting but wanted to be clear that the dialer code would infact default with other info. I have been cought with this on a C&K236i before.
Ive never completely programmed one of these as they are a bit before my time but have made various changes to them. They are straight forward enough to program so I should be right.
Will do it next week.
ATech is offline   Reply With Quote
Reply



Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

vB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


server monitor
All times are GMT +10. The time now is 07:33 AM.


Powered by vBulletin Version 3.6.0
Copyright ©2000 - 2008, Jelsoft Enterprises Ltd.

Ad Management by RedTyger