| Senior Member Join Date: Nov 2008
Posts: 180
Thanks: 10
Thanked 0 Times in 0 Posts
Rep Power: 5 ![]() | Feature 34 This is the Automatic Arming time. If enabled in Feature 36 the NX-4 will Auto Arm the specified area(s). At this time, the Code Pad will beep for 50 seconds before the panel arms. The arming process can be stopped by entering a valid code on the Code Pad. Feature 36 This feature selects which days the system will auto arm. If a zone is faulted when the panel tries to auto arm, the zone will be bypassed. For example you want the system to arm at 7Pm every night then you will need to do this, * 8 (INSTALLER CODE) 0 # 34 # 19 * 00 * (this is the time in 24hr format) 36 # 1 2 3 4 5 6 7 * (this enables the days 1=Sun, 7=Sat) Exit Exit That should arm the system at 19:00 Sun-Sat. |
| | |
| | #3 |
| Senior Member Join Date: Jan 2008
Posts: 250
Thanks: 13
Thanked 13 Times in 11 Posts
Rep Power: 8 ![]() | Im actually amazed how many business dont want you toprogram this option who are on alarm only and then the patrols notice site not armed every now & thenwould be lucky to have 10% of clients asked to program function after you have suggested it |
| | |
| | #4 |
| Senior Member Join Date: Nov 2008
Posts: 180
Thanks: 10
Thanked 0 Times in 0 Posts
Rep Power: 5 ![]() | I offer auto arm for businesses with set close times, but wont use the auto disarm feature. |
| | |
| | |
| | #5 |
| Senior Member Join Date: Jan 2008
Posts: 1,064
Thanks: 14
Thanked 144 Times in 93 Posts
Rep Power: 30 ![]() ![]() ![]() ![]() ![]() ![]() | ditto & I don't know anyone who has ever used it. I often wonder what it is there for
__________________ Licensed security installer & Trainer if I've been helpful - add to my reputation |
| | |
| | #6 |
| Senior Member Join Date: Jan 2008
Posts: 532
Thanks: 5
Thanked 8 Times in 7 Posts
Rep Power: 13 ![]() | hmmm, auto arm - good, auto disarm - retarded |
| | |
| | #7 |
| Senior Member Join Date: Nov 2008
Posts: 180
Thanks: 10
Thanked 0 Times in 0 Posts
Rep Power: 5 ![]() | I have used it for other things like freezer alarms, during the night it is armed during the day it's disarmed only because they keep triggering the temp alarm while accessing the freezers during business hours. So I would say it's more of an automation feature then a security one. |
| | |
| | #8 |
| Junior Member Join Date: Jan 2009 Age: 48
Posts: 13
Thanks: 0
Thanked 0 Times in 0 Posts
Rep Power: 0 ![]() | Bit of an odd setting really, i have never set auto disarm in any panel, and nearly all have it now. I do like the auto arm, and will suggest it to all business owners. Mitch |
| | |
| | |
| | #9 |
| Junior Member Join Date: Jan 2008
Posts: 14
Thanks: 0
Thanked 0 Times in 0 Posts
Rep Power: 0 ![]() | The nx panels dont offer auto disarm only auto arm the feature for open times in the nx panel refers to allowing certain users access only after the open time has arrived.the new Reliance panels however can auto disarm but also have a new feature which caught us by suprise the alarm is capable of rearming after the close time is reached if someone enters the building and disarms the panel and forgets to arm the systems when they leave in default the alarm looks for no activity on the detectors and if none for 45 minutes it arms itself. this time I believe can be changed to what ever you want. |
| | |
| | #10 |
| Junior Member Join Date: Jan 2009 Age: 48
Posts: 13
Thanks: 0
Thanked 0 Times in 0 Posts
Rep Power: 0 ![]() | sorry, was referring to solution and digi panels,(that i always use), and that sounds like a great feature of detector activity time before arming. What panel is that ? |
| | |
| | #11 |
| Senior Member Join Date: Aug 2008 Location: Here in Brisbane Age: 32
Posts: 281
Thanks: 3
Thanked 10 Times in 8 Posts
Rep Power: 7 ![]() | |
| | |
| | #12 | |
| Junior Member Join Date: Jan 2008
Posts: 6
Thanks: 0
Thanked 0 Times in 0 Posts
Rep Power: 0 ![]() | Quote:
I tried the above and didn't work?? | |
| | |
| | |
| | #13 |
| Senior Member Join Date: Jan 2008
Posts: 250
Thanks: 13
Thanked 13 Times in 11 Posts
Rep Power: 8 ![]() | did you set the clock time day date and year |
| | |
| | #14 | |
| Junior Member Join Date: Jan 2008
Posts: 6
Thanks: 0
Thanked 0 Times in 0 Posts
Rep Power: 0 ![]() | Quote:
I set the date and time again just to make sure and it's still not working. This is what happens: *8 = the lights blink for on,partial,exit,bypass,chime 9713 0# above lights stop blinking, only ready and power lights are on 34# = no difference to above,only ready and power lights etc have I missed a step? | |
| | |
| | #15 | |
| Senior Member Join Date: Jul 2008 Location: QLD.
Posts: 179
Thanks: 0
Thanked 2 Times in 2 Posts
Rep Power: 6 ![]() | Quote:
Used it once, good for school boarding rooms that have perimeter reeds etc to notify someone of night time antics. Kids can up & leave first thing in the morning without the supervisor having to remember to disarm. | |
| | |
| | #16 |
| Senior Member Join Date: Jul 2008 Location: QLD.
Posts: 179
Thanks: 0
Thanked 2 Times in 2 Posts
Rep Power: 6 ![]() | |
| | |
| | |
![]() |
| Bookmarks |
| Thread Tools | |
| Display Modes | |
| |
LinkBacks (?)
LinkBack to this Thread: http://www.austech.info/security-alarms/16270-networx-nx4-auto-arm.html | ||||
| Posted By | For | Type | Date | |
| Security Alarms [Archive] - Austech | This thread | Refback | 01-02-09 11:20 PM | |
| Security Alarms [Archive] - Austech | This thread | Refback | 19-01-09 11:33 PM | |
| Austech - Powered by vBulletin | This thread | Refback | 19-01-09 10:41 AM | |