    Howdy All,

    I've got a job to do here have to swap out a STU on an ademco advantage panel, now I'll be the first to admit that I dont know a lot about ademco's and before I call tech support tomorrow, apparently the unit is a advantage with a bolt on stu unit, apparently there is another bolt on unit that will turn it into a dialler, anyone know what the part number is? Or have any reading material on it, I dont know what panel type it is exactly, but i do know its a single area with 48 Zones...

    Anyone have any ideas?

    ReD



Look Here ->
  • #2
    Senior Member
    intelliGEORGE's Avatar
    Join Date
    Jan 2008
    Location
    Sydney, AUSTRALIA
    Age
    43
    Posts
    4,106
    Thanks
    884
    Thanked 1,484 Times in 691 Posts
    Rep Power
    479
    Reputation
    7236

    Default

    I called ADI yesterday about an Ademco Advantage 5115 which was connected to an MCM ICON8STU panel through a board called a P.O.M8. As far as I know the 5115 does not communicate over securitel. Pretty dodgy was of getting the site on Securitel. They should have punted the advantage and programmed the Icon8Stu. What more can you expect from the Big C?

    What version is the advantage?

  • #3
    Junior Member
    Join Date
    Apr 2009
    Location
    Melbourne
    Age
    38
    Posts
    172
    Thanks
    3
    Thanked 16 Times in 13 Posts
    Rep Power
    190
    Reputation
    104

    Default

    If its not a securitel only planel, might just have a uni-stu connected to it, rip it off and re program phone numbers and account code ect.

  • #4
    Member redozqld's Avatar
    Join Date
    Aug 2008
    Location
    Here in Brisbane
    Age
    45
    Posts
    360
    Thanks
    7
    Thanked 24 Times in 18 Posts
    Rep Power
    205
    Reputation
    142

    Default

    Honestly I dont know, we didnt want to open the panels up and upset the customers control room.... but now we have to take it over blind.... so painfull...

    ReD

  • #5
    Senior Member
    Join Date
    Jan 2008
    Location
    Sydney :P~~~
    Posts
    1,051
    Thanks
    8
    Thanked 74 Times in 54 Posts
    Rep Power
    247
    Reputation
    657

    Default

    Um, the old ademco and the new ones also had the option of securitel via a dial capture board, it was basically store and forward, so, panel dials into the capture interface, then passes the information to the stu, then in return to the cms

  • #6
    Senior Member
    Join Date
    Jan 2008
    Location
    Sydney :P~~~
    Posts
    1,051
    Thanks
    8
    Thanked 74 Times in 54 Posts
    Rep Power
    247
    Reputation
    657

    Default

    Quote Originally Posted by redozqld View Post
    Howdy All,

    I've got a job to do here have to swap out a STU on an ademco advantage panel, now I'll be the first to admit that I dont know a lot about ademco's and before I call tech support tomorrow, apparently the unit is a advantage with a bolt on stu unit, apparently there is another bolt on unit that will turn it into a dialler, anyone know what the part number is? Or have any reading material on it, I dont know what panel type it is exactly, but i do know its a single area with 48 Zones...

    Anyone have any ideas?

    ReD
    I would say, if its an old advantage parts aren't available.
    Why dont you use the stu and connect it up ti a GPRS device?
    We can do that
    1) keep old stu
    2) install GPRS device
    3) programme GPRS device as analogue stu
    done

    Line kept panel kept = happy client !

  • #7
    Senior Member
    Join Date
    Jan 2008
    Location
    Sydney :P~~~
    Posts
    1,051
    Thanks
    8
    Thanked 74 Times in 54 Posts
    Rep Power
    247
    Reputation
    657

    Default

    Quote Originally Posted by intelliGEORGE View Post
    I called ADI yesterday about an Ademco Advantage 5115 which was connected to an MCM ICON8STU panel through a board called a P.O.M8. As far as I know the 5115 does not communicate over securitel. Pretty dodgy was of getting the site on Securitel. They should have punted the advantage and programmed the Icon8Stu. What more can you expect from the Big C?

    What version is the advantage?
    Whats wrong with doing that?
    Everyone slams C all the time, for no reason

  • #8
    Member redozqld's Avatar
    Join Date
    Aug 2008
    Location
    Here in Brisbane
    Age
    45
    Posts
    360
    Thanks
    7
    Thanked 24 Times in 18 Posts
    Rep Power
    205
    Reputation
    142

    Unhappy

    Quote Originally Posted by keef82 View Post
    I would say, if its an old advantage parts aren't available.
    Why dont you use the stu and connect it up ti a GPRS device?
    We can do that
    1) keep old stu
    2) install GPRS device
    3) programme GPRS device as analogue stu
    done

    Line kept panel kept = happy client !
    Hrmm so what your suggesting is getting my hands on a permacon 1020 with a Ademco Advantage interface? I shot the question off to permaconn on thursday and havent got an answer back yet..

    thanks as always for helping my aging brain...

    ReD -- Inept concept/tecom/nx/bosch/genesis installer.... just not inept in ademco stuff...

  • #9
    Senior Member
    Join Date
    Jan 2008
    Location
    Sydney :P~~~
    Posts
    1,051
    Thanks
    8
    Thanked 74 Times in 54 Posts
    Rep Power
    247
    Reputation
    657

    Default

    Quote Originally Posted by redozqld View Post
    Hrmm so what your suggesting is getting my hands on a permacon 1020 with a Ademco Advantage interface? I shot the question off to permaconn on thursday and havent got an answer back yet..

    thanks as always for helping my aging brain...

    ReD -- Inept concept/tecom/nx/bosch/genesis installer.... just not inept in ademco stuff...
    Well, with the product we use.
    you keep the stu in the panel, and connect the phone lead from the stu to the gprs device and it captures the alarm messages from the stu and sends them onto the cms

  • #10
    Senior Member
    intelliGEORGE's Avatar
    Join Date
    Jan 2008
    Location
    Sydney, AUSTRALIA
    Age
    43
    Posts
    4,106
    Thanks
    884
    Thanked 1,484 Times in 691 Posts
    Rep Power
    479
    Reputation
    7236

    Default

    Quote Originally Posted by keef82 View Post
    Whats wrong with doing that?
    Everyone slams C all the time, for no reason
    I'm not slamming C, just pointing out the stupidity in wiring 2 panels to essentially do one thing. What happened on this site was this. Panel is Advantage and cannot communicate to a serial STU. Instead of changing the resistors in the detectors and replacing the old board. They got an MCM connected it to the POM and duplicated the zones so it reports via securitel.

    They would have done this free of charge to get the customer back to base. Hence the reason the job was done in the way it was. Probably took the installer half the time it would have to do a FULL and PROFESSIONAL upgrade.

    It's all good, the customer is in good hands now. The site is now being upgraded to a challenger system with Permacon 1020 inferface A.

  • #11
    Senior Member
    intelliGEORGE's Avatar
    Join Date
    Jan 2008
    Location
    Sydney, AUSTRALIA
    Age
    43
    Posts
    4,106
    Thanks
    884
    Thanked 1,484 Times in 691 Posts
    Rep Power
    479
    Reputation
    7236

    Default

    Quote Originally Posted by keef82 View Post
    Well, with the product we use.
    you keep the stu in the panel, and connect the phone lead from the stu to the gprs device and it captures the alarm messages from the stu and sends them onto the cms
    What panels are you performing this method on? MCM stu panels?

  • Similar Threads

    1. Ademco 6271CV
      By shonkster in forum Security Alarms
      Replies: 1
      Last Post: 12-06-09, 06:11 PM
    2. HD Satellite Receiver(advantage)
      By Jay Polra in forum Decoders
      Replies: 13
      Last Post: 12-03-09, 11:30 AM
    3. Ademco Lynx Domestic Dial?
      By kenno24 in forum Security Alarms
      Replies: 1
      Last Post: 30-10-08, 09:47 PM
    4. Ademco Vista 12, wanna add wireless
      By orica in forum Security Alarms
      Replies: 7
      Last Post: 26-05-08, 06:43 PM
    5. Ademco Vista 12 Trouble
      By too_good37 in forum Security Alarms
      Replies: 17
      Last Post: 14-03-08, 05:21 PM

    Bookmarks

    Posting Permissions

    • You may not post new threads
    • You may not post replies
    • You may not post attachments
    • You may not edit your posts
    •