Results 1 to 8 of 8

Thread: Nx16

  1. #1
    Banned
    watchdog's Avatar
    Join Date
    Jan 2008
    Posts
    2,966
    Thanks
    136
    Thanked 869 Times in 514 Posts
    Rep Power
    0
    Reputation
    8320

    Cool Nx16

    I have zero experience with NX wireless equipment. Had a bloke ring in the other day with a problem & in the course of the conversation he said he had a NX16 wireless system with Ademco w/less PIRs. Will they work with Ademco PIRs or is something else going on here ?



Look Here ->
  • #2
    Member redozqld's Avatar
    Join Date
    Aug 2008
    Location
    Here in Brisbane
    Age
    45
    Posts
    360
    Thanks
    7
    Thanked 24 Times in 18 Posts
    Rep Power
    205
    Reputation
    142

    Default NX Wireless

    I've played with the ITI Interface with the ITI Equipment, they work okay with the NX, all I can think of is that perhaps there is a stand alone box that low level inerfaces to the nx? I didnt think the ademco stuff could interface? Anyone?

    ReD

  • #3
    Senior Member
    Join Date
    Jan 2008
    Location
    Sydney :P~~~
    Posts
    1,051
    Thanks
    8
    Thanked 74 Times in 54 Posts
    Rep Power
    246
    Reputation
    657

    Default

    Clearly the person that called had no idea what they are talking about.
    NX Panels have the choice of 2 receivers,

    ITI / 433 MHZ
    Inovonics / 9XX MHZ

  • #4
    Member redozqld's Avatar
    Join Date
    Aug 2008
    Location
    Here in Brisbane
    Age
    45
    Posts
    360
    Thanks
    7
    Thanked 24 Times in 18 Posts
    Rep Power
    205
    Reputation
    142

    Default

    Did they ever make an echostream innovonics reciever for the nx? That would be uber cool... the range is so good, and throw on a repeater and awaay we go... just like the older innovonics FA equipment

    Red

  • #5
    Senior Member
    Join Date
    Jan 2008
    Location
    Sydney :P~~~
    Posts
    1,051
    Thanks
    8
    Thanked 74 Times in 54 Posts
    Rep Power
    246
    Reputation
    657

    Default

    Actually, i don't know re echostream
    .

  • #6
    Banned
    watchdog's Avatar
    Join Date
    Jan 2008
    Posts
    2,966
    Thanks
    136
    Thanked 869 Times in 514 Posts
    Rep Power
    0
    Reputation
    8320

    Cool

    Just got back from this guys place & the storey was completely different. The place had undergone extensive extensions about 2 years ago & an Ademco Vista 20 had been ripped out & an NX16 been put in with w/less PIRs for the extensions & detached garage & original FX40s for the old part of the building.
    His problem was Z11 (garage on the zone list) was flashing about 2/sec on the codepad. Pulled it down for a closer look & Z9 comes up on the code pad (because of the tamper). So if Z11 is really Z9, what is Z11? It looks like whoever installed it programmed the w/less detectors then used the lucky dip method when he mounted them. Having straightened the zones out Z11 turned out to be the PIR in the study at the far end of the house. This PIR had corrossion on the battery terminals so was cleaned up but would work only within about 20m of the panel. New batteries made no difference. He opted for the solution of swapping this one with the Hall PIR (right beside the panel) & modifying the zone list. I warned him that next problem with that PIR would mean replacement.

  • #7
    Senior Member
    Join Date
    Jan 2008
    Location
    Sydney :P~~~
    Posts
    1,051
    Thanks
    8
    Thanked 74 Times in 54 Posts
    Rep Power
    246
    Reputation
    657

    Default

    Did u programme out the old study pir

  • #8
    Banned
    watchdog's Avatar
    Join Date
    Jan 2008
    Posts
    2,966
    Thanks
    136
    Thanked 869 Times in 514 Posts
    Rep Power
    0
    Reputation
    8320

    Cool

    Quote Originally Posted by watchdog View Post
    He opted for the solution of swapping this one with the Hall PIR (right beside the panel) & modifying the zone list. I warned him that next problem with that PIR would mean replacement.
    $M waterfront mansion - doesn't like spending money

  • Similar Threads

    1. NX16 Supervisory
      By keef82 in forum Security Alarms
      Replies: 4
      Last Post: 05-11-09, 10:48 PM
    2. NX16 Alarm Entry delay Question
      By scutri in forum Security Alarms