Thread: Master PIN from home alarm C K

  1. #1
    Junior Member
    Join Date
    Jan 2010
    Posts
    12
    Thanks
    0
    Thanked 0 Times in 0 Posts
    Rep Power
    0
    Reputation
    10

    Default Master PIN from home alarm C K

    Hi

    I have a C K 236i system and need the master PIN. I downloaded the manual but it does not have it.

    thx



Look Here ->
  • #2
    Senior Member
    Join Date
    Jan 2008
    Location
    Sydney :P~~~
    Posts
    1,051
    Thanks
    8
    Thanked 74 Times in 54 Posts
    Rep Power
    247
    Reputation
    657

    Default

    A master pin code is unique to each system thats why it's not in the user manual.
    If you dont know the master pin you'll need to have someone come out and "possibly" re set it for you.

    These systems are getting on now, and not really that easy to default.
    - You need a "default" chip to get into the system is no codes are known.

    Best bet, contact the original installer
    Where are you located?

  • #3
    Senior Member
    Join Date
    Jan 2008
    Posts
    708
    Thanks
    78
    Thanked 121 Times in 75 Posts
    Rep Power
    233
    Reputation
    575

    Default

    Have you tried the default installer password page 21 under - Installer Combination

    Might be helpful if its still the same

  • #4
    Junior Member
    Join Date
    Apr 2009
    Location
    Melbourne
    Age
    38
    Posts
    172
    Thanks
    3
    Thanked 16 Times in 13 Posts
    Rep Power
    190
    Reputation
    104

    Default

    Default the master code is 1234

    As said above, may require a tech to come out and default.

    Alot of panels have the default installer code in them, if not power down and up may default installer code, if not it can be defaulted by 2 solder tabs however if installer lock out is programmed it will default the panel exept the installer code, so you have a defaulted panel and cant program, in that case as keef said a 'default' chip is needed.

    Defaulting will require re programming up zone types, delays, comunication stuff if applicable, best for a tech to do.

    If you want to see if the INSTALLER is the default, we can then help you change the master code, you can try this... however if it works and you get into programming and press any other buttons, you will be changing the programming!

    Press 0 1 2 3 4 5 * 0 # (so thats the installer code being 012345 and then the 3 buttons down the right side *0#)

    If its the right code, the power, service and arm lights will flash at the same time

    then without pressing anythign else for now, press * and # to get out, should go back to normal.

  • #5
    Junior Member
    Join Date
    Jan 2010
    Posts
    12
    Thanks
    0
    Thanked 0 Times in 0 Posts
    Rep Power
    0
    Reputation
    10

    Default

    I currently have zone 1 and 2 along with the Power green indicators flushing at the same exact rate/time.
    The service yellow is fast flushing. "which may indicate communication error"
    the ARM is steady red.

  • #6
    Senior Member
    Join Date
    Jan 2008
    Posts
    708
    Thanks
    78
    Thanked 121 Times in 75 Posts
    Rep Power
    233
    Reputation
    575

    Default

    ops
    Last edited by pieces; 16-01-10 at 10:35 AM. Reason: .

  • #7
    Junior Member
    Join Date
    Jan 2010
    Posts
    12
    Thanks
    0
    Thanked 0 Times in 0 Posts
    Rep Power
    0
    Reputation
    10

    Default

    I found out that the manual I have is the Keypad LED user manual and not the system manual.

  • #8
    Senior Member
    Join Date
    Jan 2008
    Posts
    708
    Thanks
    78
    Thanked 121 Times in 75 Posts
    Rep Power
    233
    Reputation
    575

    Default

    Quote Originally Posted by samjesse View Post
    I found out that the manual I have is the Keypad LED user manual and not the system manual.
    I have the install in PDF . PM me a email address if you want it

    Check your battery I just did mine turn power off disconnect battery and check its over 12v for starters .Mine lasted 8 years .
    Last edited by pieces; 16-01-10 at 10:46 AM.

  • #9
    Junior Member
    Join Date
    Apr 2009
    Location
    Melbourne
    Age
    38
    Posts
    172
    Thanks
    3
    Thanked 16 Times in 13 Posts
    Rep Power
    190
    Reputation
    104

    Default

    Power light flashing may indicate battery as stated, press * 6 4 # to do battery test after battery replacement.

    the zones flashing means those zones have been in alarm, press * 1 # to clear them.

    yes service lgit may indicate communication fault, im assuming it was at some stage monitored, the dialer needs to be turned off, again in programming.

  • #10
    Junior Member
    Join Date
    Jan 2010
    Posts
    12
    Thanks
    0
    Thanked 0 Times in 0 Posts
    Rep Power
    0
    Reputation
    10

    Default

    Battery reads 5.4V it suppose to be 12V, one of those ebay ones will do?

    thx

  • #11
    Senior Member
    Join Date
    Jan 2008
    Posts
    708
    Thanks
    78
    Thanked 121 Times in 75 Posts
    Rep Power
    233
    Reputation
    575

    Default

    Got mine from jaycar

  • #12
    Junior Member
    Join Date
    Jan 2010
    Posts
    12
    Thanks
    0
    Thanked 0 Times in 0 Posts
    Rep Power
    0
    Reputation
    10

    Default

    changed the battery, had 12v before installing it.
    * 1 # to clear zones. I still have zone 1 and 2 along with the Power green indicators flushing at the same exact rate/time.
    The service yellow is fast flushing. "which may indicate communication error"
    the ARM is steady red.

    what will need to be done next?

  • #13
    Senior Member
    Join Date
    Jan 2008
    Posts
    708
    Thanks
    78
    Thanked 121 Times in 75 Posts
    Rep Power
    233
    Reputation
    575

    Default

    Do the battery test as in post 9

  • #14
    Junior Member
    Join Date
    Jan 2010
    Posts
    12
    Thanks
    0
    Thanked 0 Times in 0 Posts
    Rep Power
    0
    Reputation
    10

    Default

    *64# battery test results:
    after the 2 min. test, I get the two beeps which accroding to the manual indicates a pass. However the Power light did not go off during the test as it stated in the manual.
    Now the
    Power is steady green.
    Service light is off.
    Arm light is steady red.
    Zone 5 steady red.
    Zone 1 and 2 flushging together.

  • #15
    Senior Member
    Join Date
    Jan 2008
    Posts
    708
    Thanks
    78
    Thanked 121 Times in 75 Posts
    Rep Power
    233
    Reputation
    575

    Default

    Quote Originally Posted by samjesse View Post
    *64# battery test results:
    after the 2 min. test, I get the two beeps which accroding to the manual indicates a pass. However the Power light did not go off during the test as it stated in the manual.
    Now the
    Power is steady green.
    Service light is off.
    Arm light is steady red.
    Zone 5 steady red.
    Zone 1 and 2 flushging together.
    Were getting some where .
    There are multiable issues so have to solve one at a time.
    I take it you have the alarm turned off with user code ????
    Maybe set up for silent alarm ???
    You get the count down beeps when turning on .

  • #16
    Junior Member
    Join Date
    Jan 2010
    Posts
    12
    Thanks
    0
    Thanked 0 Times in 0 Posts
    Rep Power
    0
    Reputation
    10

    Default

    I had the power adaptor disconnected during battery change and the battery was disconnected for a day. not sure if the codes are still in there.
    We bought this house not too long ago and no histroy is available.
    when putting in the user code, after a second or so, it gives a bunch of short beeps and nothing changes in the indicator lights.

    so. how can I till if the alarm is turned off or on? or at silent? I searched the manuals but could not find the info to answer your questions. thx

  • #17
    Senior Member
    Join Date
    Jan 2008
    Posts
    708
    Thanks
    78
    Thanked 121 Times in 75 Posts
    Rep Power
    233
    Reputation
    575

    Default

    I think the alarm is on .

    Are you certain you have the correct user code . ?????

    You putting a #at the end of the pin
    Last edited by pieces; 18-01-10 at 11:47 AM.

  • #18
    Junior Member
    Join Date
    Jan 2010
    Posts
    12
    Thanks
    0
    Thanked 0 Times in 0 Posts
    Rep Power
    0
    Reputation
    10

    Default

    No, I am not sure about the user code. I would like to reset /change it.

  • #19
    Senior Member
    Join Date
    Jan 2008
    Posts
    708
    Thanks
    78
    Thanked 121 Times in 75 Posts
    Rep Power
    233
    Reputation
    575

    Default

    Did you try 1234 # default

    As a master code

  • #20
    Junior Member
    Join Date
    Jan 2010
    Posts
    12
    Thanks
    0
    Thanked 0 Times in 0 Posts
    Rep Power
    0
    Reputation
    10

    Default

    I went to do that and noticed the service yellow flashing fast as before.
    * 1 # to clear memory made the service yellow flashing stop.
    1 2 3 4 # gives one beep immediatly followed by 5 shrot fast beeps.

  • Page 1 of 2 12 LastLast

    Similar Threads

    1. D8 Alarm Master Code
      By jafar in forum Security Alarms
      Replies: 9
      Last Post: 01-10-09, 03:02 PM
    2. home alarm with key tag arm/disarm
      By scottson in forum Security Alarms
      Replies: 12
      Last Post: 24-02-09, 09:22 PM
    3. Replies: 4
      Last Post: 14-12-08, 10:59 PM
    4. For Sale: GE SmartHome Alarm Kit Home Security System - $20
      By AussieM8 in forum Buy Sell and Trade
      Replies: 6
      Last Post: 11-11-08, 10:54 PM
    5. GE SmartHome Alarm Kit Home Security System
      By AussieM8 in forum Buy Sell and Trade
      Replies: 2
      Last Post: 19-01-08, 11:57 PM

    Bookmarks

    Posting Permissions

    • You may not post new threads
    • You may not post replies
    • You may not post attachments
    • You may not edit your posts
    •