Austech  


Go Back   Austech > Technology > Security Alarms
Register Forum RulesiTrader Mark Forums Read

Security Alarms Security Alarms , locks , monitoring , DIY's

Reply
 
LinkBack Thread Tools Display Modes
Old 08-03-10, 01:13 PM   #1 (permalink)
Junior Member
 
Join Date: Mar 2010
Posts: 4
Thanks: 2
Thanked 0 Times in 0 Posts
Rep Power: 0
RobMC is on a distinguished road
Default Vista 12 Setup Issues

Hi, I have installed a Vista 12E system and can't get into the programming mode.

After power up the Keypad display shows:
"Busy - Standby
Vista 12E V2.3 D1"
It holds this for about 60 seconds and then displays:
"***Disarmed***
Hit * For Faults"
It wont accept any input during or after.
Has anyone experienced this issue and is there a way arround it to get into the programming mode.
RobMC is offline   Reply With Quote
Old 08-03-10, 01:35 PM   #2
Senior Member
 
watchdog's Avatar
 
Join Date: Jan 2008
Posts: 1,064
Thanks: 14
Thanked 144 Times in 93 Posts
Rep Power: 30
watchdog is a splendid one to beholdwatchdog is a splendid one to beholdwatchdog is a splendid one to beholdwatchdog is a splendid one to beholdwatchdog is a splendid one to beholdwatchdog is a splendid one to behold
Default

I've only ever done one Vista 12 & the touchscreen was a pain in the ***. Did you hold down the * & # after powering up ?
__________________
Licensed security installer & Trainer
if I've been helpful - add to my reputation
watchdog is offline   Reply With Quote
The Following User Says Thank You to watchdog For This Useful Post:
RobMC (08-03-10)
Old 08-03-10, 02:30 PM   #3
Junior Member
 
Join Date: Mar 2010
Posts: 4
Thanks: 2
Thanked 0 Times in 0 Posts
Rep Power: 0
RobMC is on a distinguished road
Default

Hi, Yes I did that but there is no response on the keypad to any other input, although I have been able to set the keypad address to 16.
RobMC is offline   Reply With Quote
Old 08-03-10, 03:16 PM   #4
Senior Member
 
Join Date: Apr 2009
Location: Melbourne - Eastern suburbs
Age: 24
Posts: 150
Thanks: 3
Thanked 11 Times in 10 Posts
Rep Power: 5
WIDEMR is on a distinguished road
Default

If you know the installer code you of course can get in by installer code + 8 0 0

You say powered up the keypad, when you tried did you power the whole panel down and up, not just the keypad, and while its at the standby screen, hold the * and # togeather for about 5 seconds?

Ok so the keypad is address 16? is there any other keypads that may also be 16?

If theres 2 keypads with the same address, it lets you press about 3 buttons and beeps while pushing them then nothing, not even beeps, is it doing this?

Unsure if your using the only keypad or say a temp programming one at the panel ect, if so then maybe make it 17.

if you want to make the prog one 17, disconnect it from the panel so theres only 1 kp that 16, power down and up and hold * and # on power up, hopefully will get into prog at loc 20.

then go *190 and press 1 and 0 should beep 3 times, press *99 to exit, that has now enabled kp 17 to work, so connect temp kp and when it powers up, press and hold 1 & 3 and change to 17.
__________________
Security Equipment Installer
Licenced Telecommunications Cabler

Last edited by WIDEMR; 08-03-10 at 03:20 PM.
WIDEMR is offline   Reply With Quote
The Following User Says Thank You to WIDEMR For This Useful Post:
RobMC (08-03-10)
Old 08-03-10, 03:45 PM   #5
Junior Member
 
Join Date: Mar 2010
Posts: 4
Thanks: 2
Thanked 0 Times in 0 Posts
Rep Power: 0
RobMC is on a distinguished road
Default

I do have a second keypad and have set that to address 17 but I will disconnect it and try to access programming mode on the main keypad.

Thanks for the info.
RobMC is offline   Reply With Quote
Old 08-03-10, 05:24 PM   #6
Senior Member
 
Join Date: Apr 2009
Location: Melbourne - Eastern suburbs
Age: 24
Posts: 150
Thanks: 3
Thanked 11 Times in 10 Posts
Rep Power: 5
WIDEMR is on a distinguished road
Default

If the other is set to 17, and your 100% it is, shouldnt be an issue, but only takes a sec to check or to power down to rule out
__________________
Security Equipment Installer
Licenced Telecommunications Cabler
WIDEMR is offline   Reply With Quote
Reply

Bookmarks

Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Issues with alarm software and vista c_amos88 Security Alarms 3 21-05-09 03:28 AM
Vista streaming issues try FISCstream nomad Dreambox 5 02-03-09 02:33 AM
newcs setup issues Onefella Technical and Development 11 26-02-09 09:12 AM
Help Required for Newbie - Sat Dish Setup Issues Peter_82 Newbie Satellite 9 27-07-08 07:01 PM


All times are GMT +11. The time now is 04:18 AM.


Powered by vBulletin™
Copyright © vBulletin Solutions, Inc. All rights reserved.
Ad Management plugin by RedTyger