Rep Power: 0 ![]() | Hi, I have installed a Vista 12E system and can't get into the programming mode. After power up the Keypad display shows: "Busy - Standby Vista 12E V2.3 D1" It holds this for about 60 seconds and then displays: "***Disarmed*** Hit * For Faults" It wont accept any input during or after. Has anyone experienced this issue and is there a way arround it to get into the programming mode. |
| | |
| | |
| | #2 |
| Senior Member Join Date: Jan 2008
Posts: 1,064
Thanks: 14
Thanked 144 Times in 93 Posts
Rep Power: 30 ![]() ![]() ![]() ![]() ![]() ![]() | I've only ever done one Vista 12 & the touchscreen was a pain in the ***. Did you hold down the * & # after powering up ?
__________________ Licensed security installer & Trainer if I've been helpful - add to my reputation |
| | |
| The Following User Says Thank You to watchdog For This Useful Post: | RobMC (08-03-10) |
| | #3 |
| Junior Member Join Date: Mar 2010
Posts: 4
Thanks: 2
Thanked 0 Times in 0 Posts
Rep Power: 0 ![]() | Hi, Yes I did that but there is no response on the keypad to any other input, although I have been able to set the keypad address to 16. |
| | |
| | #4 |
| Senior Member Join Date: Apr 2009 Location: Melbourne - Eastern suburbs Age: 24
Posts: 150
Thanks: 3
Thanked 11 Times in 10 Posts
Rep Power: 5 ![]() | If you know the installer code you of course can get in by installer code + 8 0 0 You say powered up the keypad, when you tried did you power the whole panel down and up, not just the keypad, and while its at the standby screen, hold the * and # togeather for about 5 seconds? Ok so the keypad is address 16? is there any other keypads that may also be 16? If theres 2 keypads with the same address, it lets you press about 3 buttons and beeps while pushing them then nothing, not even beeps, is it doing this? Unsure if your using the only keypad or say a temp programming one at the panel ect, if so then maybe make it 17. if you want to make the prog one 17, disconnect it from the panel so theres only 1 kp that 16, power down and up and hold * and # on power up, hopefully will get into prog at loc 20. then go *190 and press 1 and 0 should beep 3 times, press *99 to exit, that has now enabled kp 17 to work, so connect temp kp and when it powers up, press and hold 1 & 3 and change to 17.
__________________ Security Equipment Installer Licenced Telecommunications Cabler Last edited by WIDEMR; 08-03-10 at 03:20 PM. |
| | |
| The Following User Says Thank You to WIDEMR For This Useful Post: | RobMC (08-03-10) |
| | |
| | #5 |
| Junior Member Join Date: Mar 2010
Posts: 4
Thanks: 2
Thanked 0 Times in 0 Posts
Rep Power: 0 ![]() | I do have a second keypad and have set that to address 17 but I will disconnect it and try to access programming mode on the main keypad. Thanks for the info. |
| | |
| | #6 |
| Senior Member Join Date: Apr 2009 Location: Melbourne - Eastern suburbs Age: 24
Posts: 150
Thanks: 3
Thanked 11 Times in 10 Posts
Rep Power: 5 ![]() | If the other is set to 17, and your 100% it is, shouldnt be an issue, but only takes a sec to check or to power down to rule out
__________________ Security Equipment Installer Licenced Telecommunications Cabler |
| | |
![]() |
| Bookmarks |
| Thread Tools | |
| Display Modes | |
| |
Similar Threads | ||||
| Thread | Thread Starter | Forum | Replies | Last Post |
| Issues with alarm software and vista | c_amos88 | Security Alarms | 3 | 21-05-09 03:28 AM |
| Vista streaming issues try FISCstream | nomad | Dreambox | 5 | 02-03-09 02:33 AM |
| newcs setup issues | Onefella | Technical and Development | 11 | 26-02-09 09:12 AM |
| Help Required for Newbie - Sat Dish Setup Issues | Peter_82 | Newbie Satellite | 9 | 27-07-08 07:01 PM |