Page 1 of 2 12 LastLast
Results 1 to 20 of 22

Thread: Hills Reliance 8 Security Alarm

  1. #1
    Junior Member
    Join Date
    May 2012
    Posts
    4
    Thanks
    0
    Thanked 0 Times in 0 Posts
    Rep Power
    0

    Default Hills Reliance 8 Security Alarm

    Hi
    I'll start by apologising if this has been asked before.....
    I have an intermittent fault when the alarm is unarmed in that the internal sounder occasionally goes off for no apparent reason
    There's no regular pattern to this sometimes it goes off three times in a day for a minute or so and other times it's OK for a week or more
    The panel is an RAC branded similar to a HILLS Series LCD Code Pad with the exception there is no LCD screen just a numbered screen indicating which sensor/zone is active
    Some of the sensors are hard wired and some battery powered, I've changed all the batteries along with the panel battery
    Any thoughts?
    Thanks


  2. #2
    Senior Member watchdog's Avatar
    Join Date
    Jan 2008
    Posts
    2,081
    Thanks
    87
    Thanked 485 Times in 296 Posts
    Rep Power
    73

    Cool

    Is this wired for back to base ?
    Licensed security installer & Trainer
    if I've been helpful - add to my reputation

    you were born with two ears & one mouth
    so listen twice as much as you talk

  3. #3
    Junior Member
    Join Date
    May 2012
    Posts
    4
    Thanks
    0
    Thanked 0 Times in 0 Posts
    Rep Power
    0

    Default

    Quote Originally Posted by watchdog View Post
    Is this wired for back to base ?
    Hi
    I don't understand your question......

  4. #4
    Senior Member
    Join Date
    Jan 2008
    Posts
    450
    Thanks
    77
    Thanked 42 Times in 32 Posts
    Rep Power
    17

    Default

    Watch Dog is asking is it monitored by a Control Room and if so have you contacted them to see if it has sent any signals when the noise occurs, I gather when you say internal,sounder you are talking about the internal screamer mounted somewhere in the house not the keypad buzzer

  5. #5
    Junior Member
    Join Date
    May 2012
    Posts
    4
    Thanks
    0
    Thanked 0 Times in 0 Posts
    Rep Power
    0

    Default

    Thanks
    It does not have remote monitoring, internal screamer is indeed what I have been referring to

  6. #6
    Senior Member downunderdan's Avatar
    Join Date
    Sep 2008
    Location
    Sydney Metropolitan
    Posts
    1,629
    Thanks
    99
    Thanked 368 Times in 253 Posts
    Rep Power
    55

    Default

    Disconnect it. An unmonitored alarm is little more than a noisemaking nuisance. Problem solved.

  7. #7
    Senior Member
    Join Date
    May 2010
    Posts
    1,490
    Thanks
    159
    Thanked 559 Times in 346 Posts
    Rep Power
    61

    Default

    If you want to keep using the system, get a tech out. There's an obscure issue with the aux output powering the internal siren. It can be overcome without changing the panel but to be honest, the panel should be replaced provided there's not something stupid like a single strand of copper hanging across to another terminal causing the intermittant fault.

  8. #8
    Senior Member
    Join Date
    May 2010
    Posts
    232
    Thanks
    12
    Thanked 58 Times in 52 Posts
    Rep Power
    11

    Default

    I have seen a couple of NX/Reliance panels get sticky/leaking relays on the AUX Outputs

    Changed the device to a different AUX Output or physically wire in a relay fixes the problem.

  9. #9
    Senior Member watchdog's Avatar
    Join Date
    Jan 2008
    Posts
    2,081
    Thanks
    87
    Thanked 485 Times in 296 Posts
    Rep Power
    73

    Cool

    leaky relay ???
    Licensed security installer & Trainer
    if I've been helpful - add to my reputation

    you were born with two ears & one mouth
    so listen twice as much as you talk

  10. #10
    Senior Member
    Join Date
    Oct 2010
    Posts
    247
    Thanks
    11
    Thanked 37 Times in 36 Posts
    Rep Power
    9

    Default

    Here we go again............

  11. #11
    Senior Member watchdog's Avatar
    Join Date
    Jan 2008
    Posts
    2,081
    Thanks
    87
    Thanked 485 Times in 296 Posts
    Rep Power
    73

    Cool

    My appologies if you don't like it when I take people to task when they talk BS
    Licensed security installer & Trainer
    if I've been helpful - add to my reputation

    you were born with two ears & one mouth
    so listen twice as much as you talk

  12. #12
    Premium Member bss904's Avatar
    Join Date
    Jan 2008
    Location
    NOT in Thailand
    Posts
    827
    Thanks
    368
    Thanked 132 Times in 82 Posts
    Rep Power
    28

    Default

    I understand sticking relays, but how does one diagnose and treat a leaky relay.

  13. #13
    Premium Member intelliGEORGE's Avatar
    Join Date
    Jan 2008
    Location
    Sydney, AUSTRALIA
    Age
    32
    Posts
    4,034
    Thanks
    869
    Thanked 1,446 Times in 665 Posts
    Rep Power
    152

    Default

    Quote Originally Posted by bss904 View Post
    ...but how does one treat a leaky relay.
    Selleys No More Caps!


  14. #14
    Premium Member bss904's Avatar
    Join Date
    Jan 2008
    Location
    NOT in Thailand
    Posts
    827
    Thanks
    368
    Thanked 132 Times in 82 Posts
    Rep Power
    28

    Default

    Quote Originally Posted by intelliGEORGE View Post
    Selleys No More Caps!

    Thanks George, I have just rubbed my fingers around all of my relays and they are all dry. Does this mean they are still okay, or they have all leaked out and are empty now. How does one refill them again, or are they factory sealed.

  15. #15
    Senior Member
    Join Date
    May 2010
    Posts
    232
    Thanks
    12
    Thanked 58 Times in 52 Posts
    Rep Power
    11

    Default

    Sorry for a incorrect term "leaky", but it is the best I could describe the following problem.

    I had on a few occassions seen a few NX16 panels where the Auxiliary Output 1 on the NO circuit have its relay stuck with the circuit supplying a very minimal amount of voltage of around 1-6volts. Thus the strobe would flash every minute or two all day/night when the system was not in alarm.

    While when the system was in alarm, the Auxiliary Output 1 would operate as normal.

  16. #16
    Senior Member
    Join Date
    Oct 2010
    Posts
    247
    Thanks
    11
    Thanked 37 Times in 36 Posts
    Rep Power
    9

    Default

    I too have had a similar problem with a "leaky" relay on a Solution 16, whereby a piezo screamer connected between COM+ and the NO contact of the on-board relay would emit a very soft sound, due to the presence of a few volts across the screamer. (I know in theory this shouldn't happen, but I'm just telling you what I've experienced in the "real world"). A 3k3 resistor wired across the screamer fixed the problem.

  17. #17
    Junior Member
    Join Date
    Jul 2012
    Posts
    1
    Thanks
    0
    Thanked 0 Times in 0 Posts
    Rep Power
    0

    Default Hills Reliance 8

    Quote Originally Posted by Bob P View Post
    Hi
    I'll start by apologising if this has been asked before.....
    I have an intermittent fault when the alarm is unarmed in that the internal sounder occasionally goes off for no apparent reason
    There's no regular pattern to this sometimes it goes off three times in a day for a minute or so and other times it's OK for a week or more
    The panel is an RAC branded similar to a HILLS Series LCD Code Pad with the exception there is no LCD screen just a numbered screen indicating which sensor/zone is active
    Some of the sensors are hard wired and some battery powered, I've changed all the batteries along with the panel battery
    Any thoughts?
    Thanks
    I have the same problem - unit is 3 years old - what is the fix? Thanks

  18. #18
    Senior Member
    Join Date
    Jan 2008
    Posts
    223
    Thanks
    21
    Thanked 12 Times in 11 Posts
    Rep Power
    10

    Default

    I had something similar awhile ago, I changed the outdoor siren & it has been good since

  19. #19
    Junior Member
    Join Date
    Jul 2010
    Posts
    24
    Thanks
    1
    Thanked 3 Times in 3 Posts
    Rep Power
    3

    Default

    Quote Originally Posted by alarmman View Post
    I too have had a similar problem with a "leaky" relay on a Solution 16, whereby a piezo screamer connected between COM+ and the NO contact of the on-board relay would emit a very soft sound, due to the presence of a few volts across the screamer. (I know in theory this shouldn't happen, but I'm just telling you what I've experienced in the "real world"). A 3k3 resistor wired across the screamer fixed the problem.
    Sol 16i needs a 3k3 resistor across the NO contact because it has a very low voltage because they say its a monitored output. In the box they used to have an update on a piece of paper which explained it to you. But im guessing like most Techs, these dont get read and thrown out.

  20. #20
    Senior Member watchdog's Avatar
    Join Date
    Jan 2008
    Posts
    2,081
    Thanks
    87
    Thanked 485 Times in 296 Posts
    Rep Power
    73

    Cool

    Quote Originally Posted by TechBoy View Post
    Sol 16i needs a 3k3 resistor across the NO contact because it has a very low voltage because they say its a monitored output. In the box they used to have an update on a piece of paper which explained it to you. But im guessing like most Techs, these dont get read and thrown out.
    Lets put this topic to bed once and for all. Relay outputs are a simple on/off function & by their very nature will have no voltage on the contacts unless it is put there from an external source or there is some major structural damage to the relay itself. There is no such thing as "leakage" from the primary relay coil to the switching contacts.
    Solution 16i panels do not have a relay output so you can disregard Techboys reply. The 16i has four open collector outputs.

    Open collector outputs are entirely different and by the design criteria applied to the base biasing can be made to have its collector/emitter junction o/c , s/c or anything inbetween. By designing the o/p to have a very small amount of current then the output load can be supervised to determine that it is still in circuit by monitoring this "supervisory" current. This current is so low as to not affect most loads ( horn speakers and strobes ) Unfortunately peizo screamers operate on a very low current & the supervisory current is enough to cause them to operate at a very low level.Putting the shunt resistor in circuit bypasses enough of this current from the peizo to stop this happening.

    On the Bosch (solution except 16i) panels there IS a relay output provided and it IS the designated peizo output. You CAN use it for other things and you CAN put the peizo on an O.C output but you NEED to KNOW what you are doing and stop bleeting about things not working properly.

    ahh - forum withdrawal over , feel much better.
    Licensed security installer & Trainer
    if I've been helpful - add to my reputation

    you were born with two ears & one mouth
    so listen twice as much as you talk

Page 1 of 2 12 LastLast

Bookmarks

Posting Permissions

  • You may not post new threads
  • You may not post replies
  • You may not post attachments
  • You may not edit your posts
  •