  1. Thread: Smoke Alarms

    by secure
    Replies
    4
    Views
    191

    I think in WA 240v smokes only comply in domestic...

    I think in WA 240v smokes only comply in domestic as a client could disable an security alarm (remove plug and disconnect battery) and the security system smokes would then be useless or if battery...
  2. I would think that the monitoring would require...

    I would think that the monitoring would require their own Conettix receiver, and the alarm would get addressed to that location, with an account code to link it to your alarm.
  3. Thread: Smoke Alarms

    by secure
    Replies
    4
    Views
    191

    I think rules vary state to state, My...

    I think rules vary state to state,

    My understanding is that only 240v Hard wired smoke detectors meet the requirement in domestic premises. You can change 240v detector bases to one with a relay...
  4. Replies
    6
    Views
    371

    Some other units, but 3G GSM at the moment...

    Some other units, but 3G GSM at the moment
    https://csmerchants.com.au/products/crow-3g-ip-module-3g-ip-cid-phoneapp-sms-email-reporting

    https://www.seceng.com.au/sed-30
  5. Replies
    1
    Views
    129

    Easiest way would be to upgrade board and keypad...

    Easiest way would be to upgrade board and keypad to Solution 6000 and add the Bosch 3G module to suit or use the MyAlarm app called iFob control via 3G module or Ip module

    For diallers like the...
  6. Replies
    5
    Views
    308

    Maybe power down the board, so not to short out...

    Maybe power down the board, so not to short out any pins.
    I would use a small flat blade screw driver and long nose pliers.
    It's only the plastic cap bit in the middle that is covering the pins...
  7. Replies
    6
    Views
    371

    Maybe look in to using Comnav and get push...

    Maybe look in to using Comnav and get push notifications.

    Or set the R128 to domestic dial and add Ness dialler.
    I don't think there is many 3rd party modules/diallers that can send sms alerts. I...
  8. Replies
    5
    Views
    308

    Yeah just need to remove the little cover from...

    Yeah just need to remove the little cover from the D8 board which is covering the pins.
  9. Replies
    2
    Views
    263

    On the home screen is there a button called Keypad

    On the home screen is there a button called Keypad
  10. Replies
    1
    Views
    162

    Doesn't matter which way the tamper connects. ...

    Doesn't matter which way the tamper connects.

    It may look like a fuse but not sure it actually is.
  11. Did you delete user code for user 8? User 8 has...

    Did you delete user code for user 8?
    User 8 has a user code of 0 for this feature.
  12. Correct it will not do sms with the SED unit.

    Correct it will not do sms with the SED unit.
  13. Yes needs to be a delay zone type

    Yes needs to be a delay zone type
  14. I think it might be time to replace it. Could...

    I think it might be time to replace it.
    Could try factory reset and re-program.
  15. What zone number is the sensor connected too?...

    What zone number is the sensor connected too?
    Have you check the zone type setting for the zone?
  16. Could check settings in Menu 5-2-1 and 5-2-2....

    Could check settings in Menu 5-2-1 and 5-2-2.
    Turn off dial tone detect
    Turn on extend handshake
    Try having everything off in 5-2-2
  17. Replies
    99
    Views
    41,092

    Probably the IP address of the comnav needs...

    Probably the IP address of the comnav needs updating. The comnav may of been set to static address and the new modem might be a different IP address range.
  18. Replies
    2
    Views
    327

    hmmm interesting. Doesn't say anything about...

    hmmm interesting.
    Doesn't say anything about Aust market. So see what happens.
  19. Replies
    5
    Views
    526

    I have no issue with the MyAlarm service. I have...

    I have no issue with the MyAlarm service. I have a number of clients using it.
    It's probably more reliable and secure then using a free service.
  20. Replies
    3
    Views
    345

    Maybe check zone 1 connections in sensor and...

    Maybe check zone 1 connections in sensor and panel. Test the cable for zone 1.
    If still issues on zone 1 then maybe replace the sensor.
    4 years, the battery is due for replacement.
  21. If you a powering the strike from the keypad as...

    If you a powering the strike from the keypad as well, I assume you would need to,
    Connect positive+ of the strike to the red AC/DC+ of keypad.
    On keypad, link Com(purple) to black AC/DC-
    Then put...
  22. Maybe check that the alarm box cover is back on...

    Maybe check that the alarm box cover is back on properly.
  23. Power down the alarm. Push and hold the default...

    Power down the alarm.
    Push and hold the default button and power up. If should default after 5 seconds.
  24. Try power cycling the panel. Normally the...

    Try power cycling the panel.
    Normally the outputs don't work when low battery detected.
  25. Replies
    2
    Views
    315

    Given it's age it would be worth upgrading. Most...

    Given it's age it would be worth upgrading. Most new alarms support an ip module and an app, where you can check the status of alarm and get notifications of alarm events.

    Otherwise add a 3G /4G...